As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BS 325 RBL 55-56 FLOORBEAM FOUND CORRODED. CORROSION REMOVED AS PER SRM 51-10-02, BLEND AREA D:0.037" (ORG 0.080) W:1"X L:2"X FOUND OUT OF SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG 101 LIMITS AND FLOORBEAM REPAIRED AS PER SRM 53-00-51 FIG 201 REPAIR 1.