What was found
BS 325 LBL 24-56 FLOORBEA, FOUND CORRODED. CORROSION REMOVED IAW SRM 51-10-02, BLEND OUT AREA D:0.035"(ORG 0.090")X W:1" L:3". FOUND OUT OF LIMITS IAW SRM 53-00-51 REPAIR FIG 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 325 LBL 24-56 FLOORBEA, FOUND CORRODED. CORROSION REMOVED IAW SRM 51-10-02, BLEND OUT AREA D:0.035"(ORG 0.090")X W:1" L:3". FOUND OUT OF LIMITS IAW SRM 53-00-51 REPAIR FIG 201.