What was found
SUPPORT TASK PERFORMED MFEC IAW EA 5310-04716, REV C. CRACK INDICATION NOTED AT STA 907, RT ACCOMPLISHED INTERIM REPAIR IAW ECRA 5310-05508. PLACED ON DIP TO ACCOMPLISH A PERM REPAIR PRIOR TO 50,000 FLT CYCLES. PLANNING TO CONTACT ENGINEERING AFTER 43,000 TOTAL FLT CYCLE BUT BEFORE 44,000 TOTAL FLT CYCLES FOR A PERM REPAIR. NOTE THIS ECRA IS BEING EVAL FOR DAMAGE TOLERANCE WILL LIKELY BE MADE PERMANENT.