What was found
LT HORIZONTAL STAB INSPAR LOWER SKIN SHOWS ANOMALIES AT CHEM MILL EDGES AT STAB STATIONS 223 AND 229, 2 "FWD OF AFT EDGE OF SKIN. ANOMALIES FOUND DURING C-SCAN EDDY CURRENT INSPECTION REF EA 5510-01843 REV B PERFORMED INTERIM REPAIR IAW ECRA 5510-02238.