THE INBD STRUCTURE OF THE ZEE STUB FRAME AT BS 294.5 JUST ABOVE THE R1 DOOR SILL. ZEE ANGLE IS CRACKED ACROSS THE LOWER 2 HOLES. REPAIR IAW ECRA 5311-01572.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THE INBD STRUCTURE OF THE ZEE STUB FRAME AT BS 294.5 JUST ABOVE THE R1 DOOR SILL. ZEE ANGLE IS CRACKED ACROSS THE LOWER 2 HOLES. REPAIR IAW ECRA 5311-01572.