What was found
LEFT OTBD FLOOR SUPPORT BETWEEN BS 947-967 AND LBL 50 HAS SURFACE CORROSION AT FASTENER HOLES. R & R FLOOR SUPPORT IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT OTBD FLOOR SUPPORT BETWEEN BS 947-967 AND LBL 50 HAS SURFACE CORROSION AT FASTENER HOLES. R & R FLOOR SUPPORT IAW SRM 51-40-02.