What was found
RT MLG WW AT FLOOR LEVEL RBL 31 TO 40, CRACKED IN PRESSURE BULKHEAD, APPROX 6 INCHES IN LENGTH. INSTALLED REPAIR IAW SRM 57-10-10 REP.3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT MLG WW AT FLOOR LEVEL RBL 31 TO 40, CRACKED IN PRESSURE BULKHEAD, APPROX 6 INCHES IN LENGTH. INSTALLED REPAIR IAW SRM 57-10-10 REP.3.