What was found
RIGHT HORIZONTAL STAB LOWER SKIN PANEL SHOWS CRACK INDICATION, VERIFIED HFEC CRACK IN SIZE APPROX 75 INCHES IN LENGTH. APPLIED ITERIM REPAIR IAW EC/RA 5510-02309.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT HORIZONTAL STAB LOWER SKIN PANEL SHOWS CRACK INDICATION, VERIFIED HFEC CRACK IN SIZE APPROX 75 INCHES IN LENGTH. APPLIED ITERIM REPAIR IAW EC/RA 5510-02309.