What was found
AFT CABIN AREA BS 1680 TO 1720 S17L/R WEB UNDER LAST TWO AFT FLOORBOARDS, IS DIRTY AND HAS FLUID SPILL AND SURFACE CORROSION. REMOVED CORROSION. FABRICATED REPAIR DOUBLER. TREATED AND PRIMED DOUBLER AND AREA IAW SRM 53-00-51, 53-60-51,51-10-02, 51-20-01.