What was found
BOTH VISUAL AND C-SCAN REVEALED A CRACK AT BS 129.50, 8 INCHES AFT OF DRAIN HOLE RT HORIZONTAL STAB LOWER SURFACE. REPAIRED STAB IAW SRM 55-10-01, REPAIR 11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BOTH VISUAL AND C-SCAN REVEALED A CRACK AT BS 129.50, 8 INCHES AFT OF DRAIN HOLE RT HORIZONTAL STAB LOWER SURFACE. REPAIRED STAB IAW SRM 55-10-01, REPAIR 11.