What was found
NR 2 ENGINE, NR 4 GAP COVER STRIP DAMAGED. BLENDED MINOR NICKS T/E NR 4 GAP STRIP, REQ HFEC REF SRM 54-50-70, TABLE A. ACCOMPLISHED HFEC INSPECTION TO NR 2, ENG NR 4 GAP STRIP BLENDS IAW NDT PART 6, 51-00-06. NO DEFECTS NOTED. TOTAL AREA OF DAMAGE TRIM OUT TO BE LESS THEN .010, NO FURTHER ACTION REQUIRED REF SRM 54-50-70, TABLE B.