What was found
BARE METAL IN FLOORBOARD ATTACH CHANNEL BETWEEN BS 1620-1640, RBL 11.5. GOUGES IN FLOORBOARD ATTACH CHANNEL FOUND TO BE OUT OF LIMITS IAW DWG 1508-255 & SRM 53-00-51, FIG 101, DETAIL 3. R & R CHANNEL IAW SRM 51-4 0-02, PAR 7D, FIG 12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BARE METAL IN FLOORBOARD ATTACH CHANNEL BETWEEN BS 1620-1640, RBL 11.5. GOUGES IN FLOORBOARD ATTACH CHANNEL FOUND TO BE OUT OF LIMITS IAW DWG 1508-255 & SRM 53-00-51, FIG 101, DETAIL 3. R & R CHANNEL IAW SRM 51-4 0-02, PAR 7D, FIG 12.