CORROSION ON FLOOR ATTACH ANGLE BETWEEN BS 1640 - 1620 RBL 52. REMOVED FLOOR BOARD ATTACH BETWEEN BS 1640-BS 1620 IAW SRM 51-40-02 PAR 7 FIG 12, SRM 51-40-05 & BOEING DWG 146N5664. RII INSPECTION ACCOMPLISHED.