What was found
CORROSION WAS FOUND ON THE FLOOR SUPPORT CHANNEL BETWEEN BS 1600 & 1681 LBL 57. CORROSION FOUND TO BE OUT OF LIMITS. REMOVED & REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02 PAR 7D FIG 12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION WAS FOUND ON THE FLOOR SUPPORT CHANNEL BETWEEN BS 1600 & 1681 LBL 57. CORROSION FOUND TO BE OUT OF LIMITS. REMOVED & REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02 PAR 7D FIG 12.