Service difficulty report · Sensor · Boeing 757222

Difficulty date
September 6, 2013
Submitted
September 6, 2013
Operation
Air carrier
Aircraft
N593UA
Make and model
Boeing 757222
Aircraft serial
28144
Aircraft time
54,416 hours, 20,078 cycles
Engine
Pwa PW2037
Part
Sensor
Condition
Faulty
Location
Cockpit
Stage of operation
DE
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT DECK TEMPERATURE WENT FULL COLD ON DESCENT HAD TO PUT LT PAC IN WARM STANDBY. PERFORMED BITE TEST & FOUND ZONE SENSOR FAULT ON LT PACK & ZONE TEMPERATURE CONTROLLERS. R&R FLIGHT COMPARTMENT SENSOR PN:624018-1 IAW MM:21-61-08. RESET FAULTS, RAN PACKS & CYCLED TEMPERATURE CONTROL SEVERAL TIMES. OPERATIONS CHECKED GOOD. SN ON: 036C-8726.