What was found
MAIN DECK BS 1120 TENSION TIE SHEAR WEB AREA, ONE FASTENER HOLE CRACKED. FOUND AT SLOPING SHEAR WEB & HORIZONTAL SHEAR WEB. TENSION TIE REPAIRED IAW SRM53-40-30 FIG.201 REPAIR 3. SHEAR WEB REPAIRED IAW SRM 53-40-30 FIG.201 REPAIR 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.