What was found
WHILE ACCOMPLISHING EQ3412 FOUND LEFT SIDE LOWER ATTACHMENT AREA OF WINDSHIELD SIDE POST GOUGED ON TOP SIDE OF AREA. BLENDED GOUGE REF SRM 51- 73-00. BLENDED AREA AFTER REWORK IS 1.75"X1.25"X.020" DEEP. ORIGINAL MATERIAL THICKNESS AT AREA IS .600". PER FIG 1, PAGE 8 WITHIN SERVICEABLE LIMITS, WILL NEED HFEC & PAINT RESTORED.