As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK FLOOR BEAM AT BS 1660 LBL40 TO RBL40 FOUND CORRODED. BLENDED OUT OF MD FLOOR BEAM AT BS1660 FROM LBL 40 TO RBL40. MATERIAL LOSS EXCEED SRM ALLOWABLE LIMITS. TRIMMED UPPER CHORD, ACCOMPLISHED HFEC NO DEFECT NOTED. FABRICATED & INSTALLED UPPER T-CHORD FROM LBL40 TO RBL40 IAW SRM 53-60-51 REPAIR 1.