What was found
MAIN DECK FLOOR BEAM AT BS1700 LBL2 TO RBL 28 FOUND CORRODED. BLENDED OUT CORROSION OF MAIN DECK FLOOR BEAM AT BS 1700 LBL2 TO RBL 28. MATERIAL LOSS EXCEEDED SRM ALLOWABLE LIMITS. TRIMMED UPPER T CHORD, ACCOMPLISHED HFEC, NO DEFECT NOTED. FABRICATED & INSTALLED UPPER T-CHORD STRAP FROM LBL 2 TO RBL 28 IAW SRM 53-60-51 REPAIR 1.