What was found
NOSE GEAR FAULT, RETURNED TO FIELD. INSPECTED NOSE GEAR & FOUND LOWER PROXIMITY LINK ASSEMBLY BENT & 25GA PROXIMITY SENSOR INOPERATIVE. REPLACED LINKS IAW AMM 32-21-27 & SENSOR IAW AMM 32-31-73. PERFORMED NOSE GEAR SWING IAW AMM, NO DEFECTS NOTED.