What was found
ELECTRIC GENERATOR DRIVE RT IDG FAULT LOW INTERNAL OIL PRESSURE. ADVISORY MESSAGE 2431552 LATCHED CL MODE REPLACED RT IDG IAW AMM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ELECTRIC GENERATOR DRIVE RT IDG FAULT LOW INTERNAL OIL PRESSURE. ADVISORY MESSAGE 2431552 LATCHED CL MODE REPLACED RT IDG IAW AMM.