What was found
REPEAT SFCS MESSAGES. [LEVEL 1 CHRONIC] REPEATING SFCS MESSAGES. AIRMAN SHOWS FLAP RT PROS SNSR 2 40CV OR LGCIU 2. TSM 27-51-00-810-821-A. THE FINAL FIX ON THESE ISSUES IS REPLACING THE WIRING IN THE INBD FLAP IAW THE MAINT TIP DUE CHAFING IN THE INBD FLAP STRUCTURE. IT IS ALSO BEST TO REWIRE 38 CV & 40 CV WIRING IAW MT 27-019 AS THEY RUN TOGETHER. ACCOMPLISHED WIRE REPLACEMENT & CONTACT FOR 40VCV, 7542VC TO 7502VC IAW WDM 27-51-12. NO HELP, STILL HAVE SFCS MAINTENANCE MESSAGE.