As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
B757-53-3-0571 STATION 1681 AFT GALLEY FLOOR WEB HAS CORROSION AT FLOOR BOARD ATTACH HOLES FROM HOLES FROM FUSELAGE CENTER LINE TO RT AFT GALLEY DOOR. REMOVED CORROSION AT STATION 1681 FLOOR WEB FOUND TO BE WITHIN LIMITS 10" FROM R4 DOOR STATION 168'' FOUND TO OUT OF LIMITS IAW B757-300 SRM 53-60-51. INSTALL REPAIR DOUBLER AT AREA FOUND OUT OF LIMITS STATION 1681 RBL45 IAW B757-300 SRM 53-60-51 FIG.201.