What was found
CENTER FUEL TANK IND BLANK & TOTALIZER BLANK EICAS MESSAGE FUEL QTY IND. TOTALIZER & CALCULATOR DIFFERED GREATLY, LT & RT TANKS FLUX FROM 4000-6000LBS INDICATION. CENTER BLANKED OUT & IT WAS EMPTY. DURING DESCENT TOTALIZER & CALCULATOR INDICATIONS GRADUALLY CAME TOGETHER. REPLACED FUEL QTY PROCESSOR IAW MM, GROUND CHECKED NORMAL. CENTER TANK WILL BE DEFERRED DUE TO HISTORY OF CENTER TANK PROBLEMS.