What was found
FRETTING CORROSION ON METAL FLOOR & ATTACHED FITTING BETWEEN BS1681 & BS 1720, RBL48 & RBL57. REMOVED CORROSION AT AFT DECK PLATE BS 1681 TO 1720 RBL48-57 IAW SRM 51-10-02. FOUND 3 ARE AS OUT OF LIMITS AT STATION 1692.2 RBL 50.2, STATION 1696.8 RBL 50.2, STATION 170 4.5 RBL 50.3 IAW SRM 53-60-51. FABRICATED & INSTALLED REPAIR DOUBLERS & FILLERS IAW ECRA 5330-04259. R & R AFT GALLEY FORWARD FITTING STATION 686 RBL56 IAW SRM 51-40-02.