What was found
DURING SECURITY CHECK, FOUND THREE BROKEN TERMINAL STRIPS ON BOTTOM SIDE OF MID GALLEY TABLE TOP. FOUND COVER INDEX 415 MISSING. ALL STRIPS FEED POWER TO FLOOR PROXIMITY LIGHTING. REPLACED ALL THREE TERMINAL STRIPS & INSTALLED WIRING IAW WDM 25-32-21 & WDM 25-32-22, ALL EMERGENCY LIGHTS CHECKED GOOD, IAW AMM 33-51-00.