What was found
LT HORIZONTAL STAB LOWER SKIN SHOW CRACK INDICATION AT STATION 129.50 INBD OF DRAIN HOLE APPROXIMATELY .5 INCH IN LENGTH VERIFIED HFEC. REPAIRED CRACK AT LT HORIZONTAL STAB SKIN IAW SRM 55-10-01, ID4 PG 1-5, REPAIR 11 PG 201-219.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT HORIZONTAL STAB LOWER SKIN SHOW CRACK INDICATION AT STATION 129.50 INBD OF DRAIN HOLE APPROXIMATELY .5 INCH IN LENGTH VERIFIED HFEC. REPAIRED CRACK AT LT HORIZONTAL STAB SKIN IAW SRM 55-10-01, ID4 PG 1-5, REPAIR 11 PG 201-219.