What was found
IAW EQ3055 ABILITY OF SEC 1 TO ACHIEVE PITCH CONT FAIL TO RETURN TO 0.0 + OR -0.3 IT IS AT 0.5 IAW AMM27-9 6-00-710-018-A STEP 32 PAGE 37. REPLACED SEC1 F1CE1 IAW AMM-2794-34-000-0001-A & AMM-27-34-400-0001-A, WITH NO HELP. REINSTALLED OLD UNIT. REPLACED NR 2 ELECTRONIC MODULE OF THE PITCH TRIM ACTUATOR PER MM27-44-57. NO HELP. REINSTALLED OLD UNIT. CONT OF AMIS ITEM 4862005, REPLACED MONITOR POSITION TRANSDUCER OF THE THIS ACTUATOR MM27-44-56. ALL PARAMETERS OF THE ABOVE CHECKED ARE NOW WITHIN LIMITS. OPERATIONS CHECKED GOOD.