What was found
RT FWD FUEL PUMP PRESS LIGHT IS NOT COMING OFF WITH SWITCH OFF, LIGHT TESTED OKAY. REPLACED RT FWD FUEL PUMP PRESSURE SWITCH IAW AMM, OPERATION CHECKED IS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT FWD FUEL PUMP PRESS LIGHT IS NOT COMING OFF WITH SWITCH OFF, LIGHT TESTED OKAY. REPLACED RT FWD FUEL PUMP PRESSURE SWITCH IAW AMM, OPERATION CHECKED IS NORMAL.