MD RT BS 1120 TENSION TIE AREA FOUND ONE FASTENER HOLE CRACK AT FWD CHANNEL LAYER APPROXIMATELY 1-8 IN LENGTH AT 1 O'CLOCK POSITION. TENSION TIE REPAIRED IAW SRM 53-40-30 FIG 201 REPAIR 1.