What was found
FRAME 400R CRACKED BETWEEN STRINGER 8 & 9 AT INBD FASTENER HOLE FOR AC OUTLET EXTRUSION IAW EA5310-04716. REPAIRED FRAME STATION 400R IAW EA 5310-04716 OP1 REV F.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME 400R CRACKED BETWEEN STRINGER 8 & 9 AT INBD FASTENER HOLE FOR AC OUTLET EXTRUSION IAW EA5310-04716. REPAIRED FRAME STATION 400R IAW EA 5310-04716 OP1 REV F.