Service difficulty report · Controller · Airbus A320232

Difficulty date
November 30, 2013
Submitted
December 4, 2013
Operation
Air carrier
Aircraft
N415UA
Make and model
Airbus A320232
Aircraft serial
475
Aircraft time
64,347 hours, 24,467 cycles
Engine
Iae V2527A5
Part
Controller
Part number
775C000004
Part serial
116
Condition
Faulty
Location
Cockpit Temp
Stage of operation
UK
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

COCKPIT DUCT OVERHEAT DISPLAYED ON UPPER ECAM SCREEN. TEMPERATURE SHOWS 212, HOT AIR SW IS OFF, TEMPERATURE NOT COMING DOWN, COCKPIT IS COOL. REPLACED DUCT SENSOR 15HK & ZONE CONTROLLER 8HK IAW AMM TASK 21-63-15-000-001 & AMM TASK 21-63-34-000-001-A IAW PTT 3472001. DUCT SENSOR 15HK, NO HELP. REPLACED ZONE TEMPERATURE CONTROLLER, OPERATIONS CHECKED GOOD.