What was found
AFTER TAKEOFF DOOR 2L & 2R SHOW DISARMED ON EWD & BLINK RED AT DOORS INTERMITTENTLY. ACCOMPLISHED PRESSURIZATION IAW THE JRH & AMM TO 0.9 DIFF FOUND DOORS NOT BLINKING. IF THE ARM HANDLE IS SLIGHTLY TAPED THE DOOR PRESSURIZED INDICATORS START BLINKING. FOUND L2 DOOR INNER HANDLE OUT OF RIG. INSTALLED SLIDE SAFETY PIN, ADJUSTED INNER CONTROL HANDLE IAW AMM 52-13-00-820-001-A, OPERATIONS CHECKED GOOD. PRESSURIZED AC WITH NO DEFECTS NOTED. REMOVED SLIDE SAFETY PIN.