What was found
APU NO START AFTER LANDING FAULT INDICATION. FOUND LOW OIL QTY, ECU SHOWED LOW OIL PRESS. CLEARED ECU, SERVICED & RAN APU, FOUND GEN CASE LEAKING OIL, NEEDS GENERATOR. REPLACED APU GEN IAW MM 24-21-01, OPERATIONS & LEAK CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU NO START AFTER LANDING FAULT INDICATION. FOUND LOW OIL QTY, ECU SHOWED LOW OIL PRESS. CLEARED ECU, SERVICED & RAN APU, FOUND GEN CASE LEAKING OIL, NEEDS GENERATOR. REPLACED APU GEN IAW MM 24-21-01, OPERATIONS & LEAK CHECKED GOOD.