SYS 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. CABIN PRESS CONTROL 2 FAULTED ON PFR. REPLACED CPC 2 IAW AMM 21-31-34-401, OPERATIONS CHECKED OKAY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SYS 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. CABIN PRESS CONTROL 2 FAULTED ON PFR. REPLACED CPC 2 IAW AMM 21-31-34-401, OPERATIONS CHECKED OKAY.