What was found
INBD C DUCT NR 1 ENG HAS FIRE BLANKET DISBOND IN 2 AREAS, LOWER IS APPROXIMATELY 30 X 24 INCHES, UPPER IS APPROXIMATELY 10 X 18 INCHES. REPAIRED AREA IAW SRM 78- 31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INBD C DUCT NR 1 ENG HAS FIRE BLANKET DISBOND IN 2 AREAS, LOWER IS APPROXIMATELY 30 X 24 INCHES, UPPER IS APPROXIMATELY 10 X 18 INCHES. REPAIRED AREA IAW SRM 78- 31-01.