What was found
AIR EXCHANGER FAULT DISPLAYED ON UPPER ECAM SCREEN, AIR VLV CLOSED ENG 2. IAW TOMC SHUTDOWN ENGINE, RESET A05, Q40, Q07 & F01, NO HELP. REPLACED ACOC MODULATING VLV IAW AMM79-21-51401. TESTED SYS IAW AMM79-21-51-400-010-A PARA 5AB, ALL OPERATIONS & LEAK CHECKED NORMAL. REMOVED ACOC MODULATING VLV MR 79218 DID NOT HAVE A DASH, ONLY SN1384.