What was found
CORROSION ON FRAME AT STATION 1460 & STRINGER 27L. CORROSION OUT OF LIMITS. REPLACED FRAME IAW SRM 51-40-02 PARA 4 & 7 FIG 3, 6, 8 & 12 & DRAWING 146N1029 SHEET 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FRAME AT STATION 1460 & STRINGER 27L. CORROSION OUT OF LIMITS. REPLACED FRAME IAW SRM 51-40-02 PARA 4 & 7 FIG 3, 6, 8 & 12 & DRAWING 146N1029 SHEET 3.