What was found
ENG 2 HP VLV FAULT DISPLAYED ON UPPER ECAM SCREEN. BLEED VLV SECURED CLOSED IAW MEL. DURING TROUBLE SHOOTING FOUND CONNECTOR BACK SHELL DAMAGED PCN 565-0756 IAW AWM 7 1-51-03 PG1 RDF-T. REMOVED BACK SHELL, ALL WIRE INSULATION CHECKED GOOD, INSTALLED NEW BACK SHELL & PLUG IAW AWM 71-51-03PG1. DEACTIVATED NR 2 HP VLV IAW MEL 3611T, VLV STILL FAULTING. R & R ENG NR 2 HP BLEED VALVE IAW AMM 36-11-51. OPERATIONS & LEAK CHECKED GOOD. MEL CLEARED, PLACARD REMOVED.