What was found
RT BS 1120 TENSION TIE AREA, SIX EACH HOLES FOUND CRACK AT FRAME. MAIN DECK RT BS 1120 FRAME CRACK LENGTH 0.040, BETWEEN STRINGER 7R - 12R. REPAIRED IAW SRM 53-40 -07, RPR 1, FIG 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT BS 1120 TENSION TIE AREA, SIX EACH HOLES FOUND CRACK AT FRAME. MAIN DECK RT BS 1120 FRAME CRACK LENGTH 0.040, BETWEEN STRINGER 7R - 12R. REPAIRED IAW SRM 53-40 -07, RPR 1, FIG 201.