What was found
RT BS 1120 TENSION TIE AREA ONE EACH FASTENER FOUND CRACK AT FAIL SAFE CHORD. MAIN DECK RT BS 1120 FRAME AFT FAIL SAFE CHORD CRACKED BETWEEN STRINGER 6R - 12R, CRACKED LENGTH 0.050, REPAIRED IAW SRM53-40-07, REPAIR 1, ITEM F.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT BS 1120 TENSION TIE AREA ONE EACH FASTENER FOUND CRACK AT FAIL SAFE CHORD. MAIN DECK RT BS 1120 FRAME AFT FAIL SAFE CHORD CRACKED BETWEEN STRINGER 6R - 12R, CRACKED LENGTH 0.050, REPAIRED IAW SRM53-40-07, REPAIR 1, ITEM F.