What was found
LT ENG EEC C1 STATUS MESSAGE ON CONTINUOUS. PLACED ON MEL DF849, HAS HISTORY. BITE OF PIMU FOR LEG 5 SHOWS EEC CH AB FAULT CAT 1. FMU CROSS CHECK FAIL BOTH CHANNELS. NEED TO CHECK FMU & HARNESS IAW 71-PIMU INDEX PG 62V & 62W. TROUBLE SHOT IAW FIM 71-PIMU MESSAGE INDEX PG 62V, 62W, STEPS A THRU E1. NO FAULTS NOTED R & R ENG 1 EEC IAW AMM 73-21-04 & TS IAW FIM 71-PIMU MESSAGE INDEX PG 62V & 62W. RAN ENG 1, GOT MESSAGE LT ENG CONT & LT EEC C1.