What was found
CORROSION ON FLOOR SUPPORT ANGLE AT BS 732 AT L2 ENTRY WAY. REMOVED CORROSION FROM FLOOR SUPPORT ANGLE, AND FOUND TO BE OUT OF LIMITS. R & R INNER ANGLE ALL IAW SRM 53-30 -15 FIG 1 & 101, 51-101-02 PAR 15 FIG 1,5, 51-40-02 FIG 8,12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT ANGLE AT BS 732 AT L2 ENTRY WAY. REMOVED CORROSION FROM FLOOR SUPPORT ANGLE, AND FOUND TO BE OUT OF LIMITS. R & R INNER ANGLE ALL IAW SRM 53-30 -15 FIG 1 & 101, 51-101-02 PAR 15 FIG 1,5, 51-40-02 FIG 8,12.