What was found
CORROSION ON FLOOR BEAM BS 1640, RBL 5-LBL. 5 INCHES MAIN CABIN REMOVED CORROSION ON FLOOR BEAM BS 1640, RBL 5 - LBL 5 IAW B757-300 S RM 51-10-02 PARA 15 FIG 1 & 5. ORIGINAL MATERIAL THICKNESS WAS .125 INCHES, MATERIAL REMOVED WAS .030 INCHES & WAS OUT OF LIMITS IAW B 757-300 SRM 53-00-51 FIG 101 DETAIL III. REPAIRED FLOOR BEAM IAW REO-M0845 & B757-300 SRM 53-00-31 REPAIR 11 ECR.