As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LIGHTNING STRIKE DAMAGE AT LT FUSELAGE STATION 600 AT STRINGER 17. REMOVED DAMAGE FASTENER & INSTALLED BLIND FASTENER IAW MM 53-30-95. RECHECK AT C CHECK & REPLACE WITH SOLID FASTENER AT HMV. REPAIRED LIGHTNING STRIKE AT BS 600 STRINGER 17L IAW B757-200 SRM 53-00-01 FIG 201 RPR 6 SECT II, CAT A SOLID RIVET REPAIR WITH NO REPEAT INSPECTION REQUIREMENTS.