What was found
CORROSION ON UPPER SURFACE OF FLOOR SUPPORT STATION 986 +5 LBL 32 TO LBL 45 ENTRY FLOOR STRUCT. REMOVED & INSTALLED NEW FABRICATED FLOOR SUPPORT AT STATION 986+5 LBL 32 TO 45 IAW SRM 51-40-02 & DRAWING 147A5700 REV B .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON UPPER SURFACE OF FLOOR SUPPORT STATION 986 +5 LBL 32 TO LBL 45 ENTRY FLOOR STRUCT. REMOVED & INSTALLED NEW FABRICATED FLOOR SUPPORT AT STATION 986+5 LBL 32 TO 45 IAW SRM 51-40-02 & DRAWING 147A5700 REV B .