What was found
CABIN FRAME STATION 400 BETWEEN STRINGERS 8L - 9L HAS CRACK AT FASTENER HOLE. CUTOUT DAMAGE & INSTALLED REPAIR ANGLE A & B IAW EA 5310-047 16 REV F.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FRAME STATION 400 BETWEEN STRINGERS 8L - 9L HAS CRACK AT FASTENER HOLE. CUTOUT DAMAGE & INSTALLED REPAIR ANGLE A & B IAW EA 5310-047 16 REV F.