What was found
CRACK WAS FOUND ON THE FRAME HOLES WHICH ATTACH THE BRACKET BETWEEN STRINGER 8R - STRINGER 9R, STATION 747 L=0.1 INCH. FABRICATED ANGLES IAW EA 5310-04716 REV F STEP 9 FIG 3. MATERIAL 7075-TO CLAD AL SHEET. REMOVED CRACK IAW EA 5310-04716 REV F STEP 9 FIG 3 NR-51-001 VERIFY THIS WORK ACCOMPLISH. LOCATION & DRILLED HOLES ON THE REPAIR ANGLES ON THE FRAME IAW NDT PART 6 51-00-00 FIG 23. INSTALLED REPAIR PART, APPLIED CIC AT REWORKED AREA IAW EA 5310-04716 REV F FIG 3. ACP RII INSPECTION PER ALL CRITICAL STEPS IN GMM 09-25-05.