What was found
CRACK WAS FOUND ON THE FRAME HOLES WHICH ATTACH THE BRACKET BETWEEN STRINGER 8R - STRINGER 9R, STATION 480 L=0.1 INCH. FABRICATED ANGLES IAW EA 5310-04716 REV F STEP 9 FIG 3. LOCATED & DRILLED THE HOLE IN THE REPAIR PARTS. COLD WORKING 7075-TO CLAD AL SHEET. REMOVED THE DAMAGE IAW EA5310-04716 REV F STEP 9 FIG 3. INSTALLED REPAIR PARTS, APPLIED CIC AT REWORKED AREA IAW EA 5310-04716 REV F STEP 9 FIG 3.