As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT NR 2 ENTRY DOOR CUT OUT LOWER MAIN SILL INNER CHORD SEVERAL CORROSION S=4"*2" STATION 890 - STATION 1010, RBL 40 - RBL 60. REMOVED THE CORROSION PART IAW SRM 51-40-02 P1 REV 51. LOCATED & DRILLED HOLES IAW SRM51-40-02 P1 REV 51 FOUND SHORT EDGE MARGE SEE GFS0422052. INSTALLED THE NEW PART IAW SRM 51-40-02 P1 REV 51 & DWG 747A8501.